13
The K8045 can store 9 sixteen-character messages, 1 for each input and a 9th
which is displayed when no inputs are active.
Briefly press SW2 ‘PROG’ to enter program mode
The display shows ‘INPUT 1...9 / S / Q : ‘ and a flashing cursor
To enter a message for input 1 :
Type ‘1’ ‘ENTER’
The unit now displays ‘TRIGGER (1/0):’ and a flashing cursor
If you want the message to appear when the input is active (grounded),
type ‘0’ ‘ENTER’
In case you want the message to appear when the input is not active (left open),
Type ‘1’ ‘ENTER’
(If you do not want to change the settings for this input, press ‘BACKSPACE’ to
return to the previous menu)
The display now show the current message for this input.
If you do not wish to change the message for this input, press ‘BACKSPACE’ to
return to the input selection menu
If you wish to change the current message, simply type a new message and
press ‘ENTER’
Your message is now stored and the unit returns to the input selection menu
You can now enter messages for all inputs (1..9).
Message 9 is displayed when no input is active and does not allow you to enter
a trigger setting.
To exit programming mode, type ‘Q’ (capital).
(Note : You can download software from our
website www.velleman.be which makes it very
easy to store, edit and transfer messages, with-
out the need for a terminal program)
26. Entering messages with a terminal program :
Message entering
Vue de la page 12