The K8050 features 4 operating modes, selectable with diodes D16 and D17.
1) 15 independent outputs.
2) 15 rotary outputs
3) 7 independent outputs & 8 rotary outputs.
4) 7 rotary outputs & 8 rotary outputs (independent from each other).
Momentary (push button-) function : Hold the key to activate the output and release the key to deactivate it.
Toggle function : Operates according to the principle of a classic switch, i.e. you have to press the key once to
switch and press again to deactivate it.
15. set - up
MODE D16 D17
1 Not mounted Not mounted
2 Not mounted Mounted
3 Mounted Not mounted
4 Mounted Mounted