11
The drawing below shows a connection example with open collector outputs
(e.g. K8000 computer interface board, or K8050 (K6711) remote control
receiver). The open collector inputs are also available via modular connector
SK19, which allows easy and fast connection to a control circuit.
16. Interfacing with open collector outputs
24VAC LOAD1N
1C2C3CC
VELLEMAN K8006
L
SUPPLY
C
LOAD2NLOAD3NLOAD4NLOAD5NN
12345
DANGER
HIGH
VOLTA GE
24VAC
PRIM
L N
LN
PUSH BUTTONS
AC POW ER
CIRCUIT
BREAKER
16A
TRANSFORMER
OPEN
COL L EC TO R
INPUTS
4C5
SW1 SW2 SW3 SW4 SW5
12345C
COLLECTOR
OPEN
OUTPUTS
Interfacing with open collector outputs
Fig. 2.0